Kaunggulan produk
Naha Kabinet 241kWh Ieu BESS Nangtung
Kelas A LiFePO4 · 314Ah
1P240S tunggal-string - euweuh saimbangna paralel. 100% pabrik-disaring Kurang atawa sarua jeung 3mV simpangan per IEC 62620.
Cairan / cooling hawa Configurable
Glycol cold plates for >Lingkungan 40 derajat: ± 2 derajat kaseragaman sél, 15–20% siklus hirup leuwih panjang vs hawa-tiis di wewengkon panas.
Sadayana-dina-Hiji Modular Terpadu
Batré + PCS + BMS + EMS + STS + cooling + suprési seuneu dina hiji IP55 dipager outdoor. Nol dina-situs assembly.
5-Lapisan Arsitéktur Kasalametan
Sél BMS → modul sekering → rak panghalang termal → kabinét suprési seuneu → Sistim darurat megatkeun. Masing mandiri.
Langkung ageung atanapi sami sareng 89% DC Round-Efisiensi Perjalanan
IGBT-based PCS. AC-AC ≥86%. Liquid-cooled maintains 1–2% higher efficiency in >lingkungan 40 derajat.
Awan EMS + Jauh O&M
Dasbor SOC/SOH/daya/suhu nyata-waktos. Tanda anomali. apdet firmware OTA. API pikeun integrasi SCADA.
Arsitéktur Sistim
Di jero Kabinet Terpadu BESS
Genep subsistem, hiji dipager. Taya cocog éksternal diperlukeun.
125KW Bi-PCS arah
Grid-diikat + pareum-modus grid. STS Kurang atawa sarua jeung 20ms mindahkeun . 380V/400V/415V 3-fase, 50/60Hz.
Sistem Manajemén Énergi (EMS)
Puncak cukur, TOU arbitrage, solar self-konsumsi, réspon paménta. SCADA API.
Sistem Manajemén Batré (BMS)
Sél -level V/I/T monitoring. Balancing aktip dina senar 240S. SOC / SOH ± 2% akurasi.
Saklar Transfer Statik (STS)
Sub-20ms grid↔off-grid. UPS-kontinuitas beban kritis kelas.
Manajemén termal & cooling
Hawa: IP55 ventilasi paksa. Cairan: glikol pelat tiis, ± 2 derajat uniformity.
Sistim suprési seuneu
Haseup/gas ngadeteksi → aerosol gancang → banjir perfluorohexanone. Nol résidu.
241kWh Kabinet BESS spésifikasi
Parameter batré
| Modél | CBS240 | |
| Tegangan dipeunteun | 768V | |
| Kapasitas dipeunteun | 314Ah | |
| Énergi | 241 kWh | |
| Rentang tegangan operasi | 624-864V | |
| Runtuyan jeung Paralel Connection | 1P240S | |
Parameter Sistim
| Grid Standar | 3L+N+PE |
| Dipeunteun Power | 125KW |
| Rentang tegangan grid | 380V (-15% nepi ka +10%) |
| Dipeunteun Ayeuna | 190A |
| Efisiensi Konversi maksimum | 97% |
| Kamampuhan ngamuat leuwih- | 110% 1 mnt |
| Frékuénsi dipeunteun | 50Hz |
| Rentang Frékuénsi Grid | 50Hz±2,5Hz |
| Laju Distorsi Total Grid (THDi) | Kurang atawa sarua jeung 3% dina beban pinuh |
| Tilu{0}}fase Unbalance Degree | 100% |
| Faktor kakuatan | -1~+1 adjustable |
Parameter umum
| Sistim cooling | Pendinginan cair (pendingin hawa opsional) |
| Seuneu Extinguishing System | Perfluorohexanone + aerosol dual-tahap |
| Suhu Operasi | -20 ~ 50 derajat |
| Geuning | Kurang atawa sarua jeung 60dB |
| Kelas IP | IP54 |
| Ukuran (W × D × H) | 1195×1400×2140mm (47,1×55,1×84,3 inci) |
| Beurat | Kurang atawa sarua jeung 2,8 ton |
Catetan:kaayaan baku. Cooling, inverter, certifications configurable per proyék.Unduh Lembar Data lengkep (PDF)
Kabinet BESS sacara resmi didaptarkeun salaku cocog ku sababaraha pabrik inverter anu diakui sacara global. Masing-masing produk parantos ngalaman uji sareng validasi anu ketat pikeun mastikeun komunikasi lancar, operasi anu dipercaya, sareng kasaluyuan pinuh dina sagala rupa platform inverter.












Sertifikasi

241kWh Kabinet BESS - FAQ Téknis
P: Naha 241kWh nganggo 1P240S tibatan senar paralel, sareng naon -dampak dunya nyata?
A: 1P240S nempatkeun 240 sél dina runtuyan kalawan enol string paralel. Ieu ngaleungitkeun inter-ketidakseimbangan arus string - akar umum tina kapasitas prématur luntur dina multi-desain paralel. Kalayan ngan hiji senar, BMS ngokolakeun profil muatan/discharge anu langkung saderhana sareng tiasa diprediksi. Dagangna-pareum: unggal sél 314Ah kudu lulus saringan asup anu leuwih ketat (Kurang atawa sarua jeung 3mV, Kurang atawa sarua jeung 5mΩ) pikeun ngahindarkeun -degradasi link. Dina prakna, ieu hartina siklus hirup leuwih konsisten dina sakabéh 241,15 kWh - pamaké ningali kirang divergénsi SOH antara taun 3 jeung 10 dibandingkeun jeung 2P atawa 4P arsitéktur total kapasitas sarupa.
Q: Upami sél asup kana runaway termal di jero kabinét ieu, naon anu nyegah éta ngahontal modul anu padeukeut?
A: Lima lapisan seuneu sequentially: sél BMS umbul anomali dina<500ms and isolates it; module fuses cut fault current before propagation; rack-level ceramic barriers block heat transfer physically; if temperature or gas levels still rise, the cabinet's perfluorohexanone + aerosol system floods the compartment automatically (no residue, no electronic damage); and finally the STS disconnects the entire cabinet from the grid in ≤20ms. Because this is LiFePO4 - not NCM or NCA - the failing cell does not release oxygen, which is the main propagation driver in ternary chemistries. No layer depends on another to function. For a deeper look at how UL testing validates these safety layers, see our guide on sertifikasi BESS UL.
Q: 241kWh nominal, tapi sabaraha énergi AC sabenerna kaluar per siklus pinuh?
A: At default EMS settings (5% bottom SOC reserve, 2% top), usable DC capacity is ~224 kWh per cycle. Multiply by ≥86% AC-AC round-trip efficiency (at 25°C, 0.5C) and you get roughly 193–207 kWh AC delivered to load - the range depends on ambient temperature and C-rate. In hot climates (>40 derajat ), varian cair-cooled nganteurkeun efisiensi 1–2% leuwih luhur batan hawa-cooled sabab kontrol termal anu leuwih ketat ngurangan résistansi internal. Upami proyek anjeun peryogi kaluaran maksimal, cadangan EMS SOC tiasa disaluyukeun - tapi cadangan anu langkung heureut diperdagangkeun umur panjang kanggo kapasitas jangka pondok-.
P: Kabinét ieu beuratna Kurang atanapi sami sareng 2,8 ton - naon anu diperyogikeun ku situs pikeun ngadukung éta?
A: Pondasi: tingkat pad beton atawa pigura baja dipeunteun Greater ti atawa sarua jeung 4.000 kg. Unit (1400 × 1300 × 2387 mm) peryogi 800mm clearance di hareup pikeun aksés jasa jeung 300mm di sisi séjén pikeun ventilasi. Standar anu langkung ageung atanapi sami sareng 3.5t forklift tiasa nempatkeun éta - henteu aya bango. Listrik: 3 -fase 380/400/415V sambungan AC, grounding kode lokal, kabel Ethernet atawa RS485 pikeun EMS. Polinovel ngirimkeun gambar pondasi dimension sareng panduan rute kabel kalayan unggal pesenan, sareng nawiskeun pangrojong komisi jauh gratis liwat telepon pidéo.
Q: Nalika kuring paralel 4-8 tina cabinets 241kWh ieu, kumaha EMS nyegah sepuh henteu rata?
A: The centralized EMS runs a weighted SOC balancing algorithm each control cycle (~100ms): cabinets with higher SOC discharge proportionally more, lower-SOC units receive more charge current. This keeps all cabinets within a tight SOC band and prevents any single unit from cycling disproportionately - which is the main cause of uneven aging in parallel BESS systems. Each cabinet retains independent BMS and PCS, so if one trips on a fault, the others absorb its load seamlessly. Communication: Modbus-TCP over Ethernet, 1-second polling. For systems >2 MWh, Polinovel nyarankeunwadahna BESSpikeun hadé $ / kWh dina skala.
P: Naha PCS 125KW tiasa ngadamel grid-puncak cukur diikat siang sareng mareuman-grid cadangan wengi dina pamasangan anu sami?
A: Sumuhun - EMS ngarojong waktos -switch mode terjadwal. Conto: grid-arbitrase TOU diikat 6AM–10PM, otomatis pareum-grid backup 10PM–6AM. The STS handles unggal transisi dina kirang ti atawa sarua jeung 20ms. Pikeun setelan dimana sababaraha beban kudu dihijikeun-samentara batur kaluar-grid sakaligus (beulah-beus), switchgear tambahan diperlukeun saluareun konfigurasi standar.Kontak Téknik Polinovelpikeun pamisah-proyek beus scoping jeung harga.
Wawasan Téknis pikeun C&I Energy Storage

Sabaraha Biaya BESS Saleresna dina 2025?
Harga turnkey, biaya disumputkeun, sareng metodologi ROI pikeun proyék kabinét & wadahna.

Panyimpenan Énergi Skala Besar - Naon Anu Dirobih?
Lilana dagang -offs, kendala manufaktur, sareng kunaon software EMS langkung penting tibatan anu disangka.

Nalika Skala tina Kabinet ka Wadahna BESS
Ambang kapasitas, titik putus biaya, sareng kerangka kaputusan faktor formulir.
panas Tags: 125kw 241kwh Sistim gudang énergi kabinét outdoor, Cina 125kw 241kwh outdoor Sistim gudang énergi kabinét pabrik, suppliers, pabrik